Transformer Station
video

Transformer Station

Dear Esteemed Partner, Are you in pursuit of a transformer manufacturer that not only meets but exceeds your expectations in innovation and reliability? Changsong is your strategic ally, dedicated to powering your success with our cutting-edge Booster Transformers. Why Choose Changsong?...
Send Inquiry
Product Introduction

Dear Esteemed Partner,

Are you in pursuit of a transformer manufacturer that not only meets but exceeds your expectations in innovation and reliability? Changsong is your strategic ally, dedicated to powering your success with our cutting-edge Booster Transformers.

Why Choose Changsong?

Innovative Excellence: Our commitment to innovation ensures that you benefit from the latest advancements in transformer technology, delivering unparalleled performance.

Unwavering Reliability: Built for endurance, our transformers are designed to stand the test of time, offering you peace of mind and consistent power.

Custom Solutions: Your unique needs drive our engineering process, resulting in transformers that are tailored to your specific operational requirements.

Enduring Partnership: We see our relationship with you as more than a transaction; it's a long-term partnership where we support your growth and sustainability.

Partner with Changsong, and together, let's transform your power needs into a sustainable advantage.


Technical parameter

Project

unit

FKN12-12 load switch

FKN12-12 Vacuum load switch

Rated voltage

KV

10

Maximum operating voltage

kV

12

Rated frequency

Hz

50

Rated current

A

630

Rated breaking load current

A

630

Heat stable current

kA/S

20/2

20/4

Dynamic stable current

kA

50

50

Short-circuit closing current (peak)

kA

50

50

Full load breaking times

frequency

2000

10000

Mechanical life

frequency

2000

10000

1min power frequency withstand voltage (phase to phase and ground)

kA

42

42

Lightning impulse voltage (relative and to ground)

kA

75

75

Technical parameters of high voltage fuse

Model number

Rated voltage(KV)

Breaking current(A)

Breaking current(A)

Melt frontage breaks current(A)

Britain

China

SDL*J

XRNT-12

12

40

31.5

6.3,10,16,20,25,31.5,40

SFL*J

XRNT-12

12

100

31.5

50,63,71,80,100

SKL*J

XRNT-12

12

125

31.5

125

1

 

2

3

4

FAQ
1. Altitude?
For projects situated at elevations exceeding 1000 meters, our team of specialists is equipped to adapt our products. This customization guarantees they are ideally matched for high-altitude applications, sustaining the equivalent level of performance and dependability you've come to expect.
2. The ambient temperature used?
Need to be in the range of -25℃-+40℃
3.Can it be customized?
If you have any questions or particular needs, please feel free to reach out to our sales team. They are well-prepared to offer you comprehensive details and tailor services to your individual requirements.

 

 

 