Transformer Station
Dear Esteemed Partner,
Are you in pursuit of a transformer manufacturer that not only meets but exceeds your expectations in innovation and reliability? Changsong is your strategic ally, dedicated to powering your success with our cutting-edge Booster Transformers.
Why Choose Changsong?
Innovative Excellence: Our commitment to innovation ensures that you benefit from the latest advancements in transformer technology, delivering unparalleled performance.
Unwavering Reliability: Built for endurance, our transformers are designed to stand the test of time, offering you peace of mind and consistent power.
Custom Solutions: Your unique needs drive our engineering process, resulting in transformers that are tailored to your specific operational requirements.
Enduring Partnership: We see our relationship with you as more than a transaction; it's a long-term partnership where we support your growth and sustainability.
Partner with Changsong, and together, let's transform your power needs into a sustainable advantage.
Technical parameter
|
Project |
unit |
FKN12-12 load switch |
FKN12-12 Vacuum load switch |
|
Rated voltage |
KV |
10 |
|
|
Maximum operating voltage |
kV |
12 |
|
|
Rated frequency |
Hz |
50 |
|
|
Rated current |
A |
630 |
|
|
Rated breaking load current |
A |
630 |
|
|
Heat stable current |
kA/S |
20/2 |
20/4 |
|
Dynamic stable current |
kA |
50 |
50 |
|
Short-circuit closing current (peak) |
kA |
50 |
50 |
|
Full load breaking times |
frequency |
2000 |
10000 |
|
Mechanical life |
frequency |
2000 |
10000 |
|
1min power frequency withstand voltage (phase to phase and ground) |
kA |
42 |
42 |
|
Lightning impulse voltage (relative and to ground) |
kA |
75 |
75 |
Technical parameters of high voltage fuse
|
Model number |
Rated voltage(KV) |
Breaking current(A) |
Breaking current(A) |
Melt frontage breaks current(A) |
|
|
Britain |
China |
||||
|
SDL*J |
XRNT-12 |
12 |
40 |
31.5 |
6.3,10,16,20,25,31.5,40 |
|
SFL*J |
XRNT-12 |
12 |
100 |
31.5 |
50,63,71,80,100 |
|
SKL*J |
XRNT-12 |
12 |
125 |
31.5 |
125 |




FAQ
1. Altitude?
For projects situated at elevations exceeding 1000 meters, our team of specialists is equipped to adapt our products. This customization guarantees they are ideally matched for high-altitude applications, sustaining the equivalent level of performance and dependability you've come to expect.
2. The ambient temperature used?
Need to be in the range of -25℃-+40℃
3.Can it be customized?
If you have any questions or particular needs, please feel free to reach out to our sales team. They are well-prepared to offer you comprehensive details and tailor services to your individual requirements.